Shenlong Pump News Center

pump industrys new and pump technology articles

we provide advice of submersible pump installation,submersible pump working,submersible pump troubleshooting,submersible pump stopped and other pump technology articles.

Technology

首页 > News > Technology

Maintenance cycle and content of multi-stage boiler feed pump

Multistage boiler feed water pump
 
Middle repair content 
1.Check the pump outlet side shaft end is beyond the mark line. 
2.Disassemble the coupling and check .
3.Clean the bearing box and check the bearing. 
4.Bearing box water jacket and the cooling water pipe cleaning. 
5.Check the cleaning filter and outlet valve. 
6.Check the stuffing box, wear sleeves, replace the packing. 
7.Check whether there is leakage of pump body. 
8.Check the loose bolt and tighten the cylinder. 
9.Measuring base sinking and recording data. 
10.Check whether the base bolts are loose and tighten. 

11.Pump group review.  

Maybe you are interested in following articles

Chat Online & Leave Message

Please send email to : info@apkpump.com
Or leave message in following form.
@
Please briefly tell us your needs (pump type, working envirment)