Shenlong Pump News Center

pump industrys new and pump technology articles

we provide advice of submersible pump installation,submersible pump working,submersible pump troubleshooting,submersible pump stopped and other pump technology articles.

Technology

Home > News > Technology

Cause and treatment method of high current of centrifugal pump

Centrifugal  pump

 

1. Process medium relative density and viscosity index:  

 Processing method: check the material component to make its viscosity and relative density and design value is in line with the process operator to adjust  

2. Electrical failure  :

 Processing method: check the circuit breaker heater setting value, check the voltage, three-phase current should be balanced, the error is not greater than 3%  

3. When the pump starts, the outlet valve is open, the resistance in the outlet pipe is too small :

Processing method: the outlet valve is closed, the pump starts slowly open the outlet valve .

4. Balance tube is not smooth : 

Processing method: clear the balance tube  

5. Pump assembly is not good, static and dynamic part of the friction or stuck : 

Treatment method: to pump the assembly, check the fit clearance, bearing clearance, mechanical seal, and so on, and strictly according to the design requirements to adjust .  

Chat Online & Leave Message

Please send email to : enquiry@apkpump.com
Or leave message in following form.
@
Please briefly tell us your needs (pump type, working envirment)