Shenlong Pump News Center

pump industrys new and pump technology articles

we provide advice of submersible pump installation,submersible pump working,submersible pump troubleshooting,submersible pump stopped and other pump technology articles.

Technology

Home > News > Technology

Requirements for operation of centrifugal pumps

 

Centrifugal pump

The use and operation of the centrifugal pump should meet the following requirements:

1.  The steering of the driver should be the same as that of the pump;

2. Identify coaxial pipeline pumps and steering pump;

3. The fixed connection parts shall not be loose, the lubricating parts filling lubricant specifications and quantity should be in accordance with the provisions of the technical documents of the equipment;

4. Pre lubrication requirements of the parts should be pre lubricated as required;

5. Each indicating instrument, the safety protection device should be sensitive, accurate and reliable;

6. Turning gear should be flexible, no abnormal phenomenon;

7. High temperature pump before commissioning should pump body for preheating temperature rise evenly, hourly temperature rises shall not greater than 50 DEG C; and the temperature difference between the working fluid inlet piping shall not be greater than 40 DEG C of the surface of the pump body;

8. The set to eliminate the connecting device of the impact of temperature rise, set the bypass connecting device to provide cooling water.

Chat Online & Leave Message

Please send email to : enquiry@apkpump.com
Or leave message in following form.
@
Please briefly tell us your needs (pump type, working envirment)