Water pump installation and fault analysis and treatment method

Water pump

Analysis and treatment of common faults of water pump 

Different types of pumps, the performance of the form of failure is not the same, but summed up. 

1. Inadequate flow:

Causes: lack of impact of water flow is the water pipe leakage, valve leakage; water plugging; water depth at the end of valve insufficiency; the pump speed is too low; the impeller sealing ring or excessive wear; high water exceed the standard. 
Treatment methods: check valve and water pipe, blocked the leak source; clean water inlet sludge or blockage; water depth at the end of valve must be greater than 1.5 times the diameter of the water inlet pipe. Increasing the water depth at the end of valve; check the power supply voltage, improve the pump speed, sealing ring or impeller repair or replacement; reduce water pump installation, or replacement of high lift pump. 

2. Power consumption is too large:

Cause: pump speed is too high; pump shaft bending or pump shaft and motor shaft misalignment or not parallel; selection of the pump head is not suitable; pump suction or sediment blockage; motor ball bearing damage. 
Treatment methods: check the circuit voltage, reduce the pump speed; the relative position correction of pump shaft or adjust the pump and motor; appropriate lift pump; clean sediment or blockage; the replacement of ball bearing motor. 

3.Severe vibration or noise of the pump body: 

Cause: pump installation is not strong or pump installation is too high; motor ball bearing damage; pump shaft bending or the motor spindle is not concentric, not parallel, etc.. 
Methods: the installation of a stable pump or reduce the installation height of the pump; replacement motor ball bearings; correction of the main shaft of the bend or adjust the relative position of the pump and motor. 

4.The drive shaft or motor bearings overheating:

Cause: the lack of lubrication or bearing rupture, etc.. 
Method of treatment: fill in the lubricating oil or replace the bearing. 

5. No water pump:

Cause: pump body and suction pipe is not filled with water; the water level is lower than the pump water pump pipe, water pipe burst and so on. 
Processing method: remove the end of valve failure, filled with water; reduce water pump installation, and make the water pipes under the water level in the dynamic, or moving water pipes or filters and then pumping; repair or replacement of water pipes. 
 