1. Pump inclined to reduce the elbow. The water pump is inclined to be installed or the spiral case is turned, and the water outlet is opposite to the pool.
2. Shorten the pipeline. Remove 1 meters of steel pipe, 10 hours can save diesel 0.21 kg.
3. To expand the size of the water outlet pipe. The 4 meters long 10 cm water hose for 15 cm tube, 10 hours to save 0.5 kg of diesel.
4. In the case of the water can be kept clean, can remove the filter.
5. Change the ring, adjust the axial gap. To prevent the impeller mouth ring and the axial gap is not appropriate, the use of the pump should be adjusted according to the factory.
6. To eliminate the blockage of the pipeline in time. Foreign bodies remain in the inlet pipe, impeller or diversion shell, will be used to reduce the amount of water.
7. To prevent the pump intake. Pump into the air, the water will be significantly reduced, to deal with the seal parts inspection and maintenance.
8. Using the coupling direct drive instead of flat belt, can improve the transmission efficiency.