Shenlong Pump News Center

pump industrys new and pump technology articles

we provide advice of submersible pump installation,submersible pump working,submersible pump troubleshooting,submersible pump stopped and other pump technology articles.

Technology

Home > News > Technology

Matters needing attention when using the submersible pump

 Matters to be noted when using a submersible pump:

1. The installation of leakage protector is also called the protection of life, it's role from the "life" of the three words can be understood. Because submersible pump works under water, easy to leakage caused by power loss or even lead to electric shock accident. If equipped with leakage protector, as long as the submersible pump leakage values over the action current of leakage protector value (generally not more than 30 MA), earth leakage protection device will cut off the submersible pump power, avoid wasting electricity leakage, to ensure safety.
2. Abnormal power supply voltage of the rural areas due to low voltage power supply line is relatively long, the end of the line is often too low voltage. When the phase voltage below 198 volts, line voltage lower than 342 volts, submersible pump motor speed to drop, when up to 70% less than the rated speed, start centrifugal switch closed, resulting in start winding head of time electricity and heat and even burn winding and capacitor. On the contrary, caused by high voltage motor overheating and burn winding. Therefore, the submersible pump in the operation, the operator must observe the power supply voltage, if less than 10% of the rated voltage, higher than the rated voltage of 10% or more, should be to stop the operation of the motor, to find out the reasons and troubleshooting.
3. Do not let the submersible electric pump long-term overload of work to avoid submersible pump long-term overload of work, do not draw large sediment water and always observe the current whether in the nameplate on the provisions of the numerical value, if too much current is found should be down to check. In addition, the electric pump running time should not be too long, so as to avoid overheating and burning motor.
4. To avoid frequent switching do not frequently switch submersible pump, this is because the pump switch to stop the return will produce, if an immediate start, will start the motor load, leading to the starting current is too large to burn winding. As the start when the current large, frequent start will burn submersible pump motor windings.
5. And a motor direction of rotation to the right should clarify the motor direction of rotation, there are many types of submersible pump when the forward and inversion can be water, but the reverse when the water is small, current, its reversal time long will damage the motor windings.
6. Cable installation and the submersible pump insulation resistance requires the installation of submersible pumps cables to overhead power lines not too long. Submersible pump water or put forward not to make the cable force, so as not to cause power line fault. When the submersible pump works do not sink into the mud, otherwise it will lead to poor motor cooling motor windings burned. When installation, the insulation resistance of the motor should not be lower than that of the.
7. Often check problems and timely repair normally should always check the motor, as found under the cap cracks, rubber seal ring damage or failure, should be replaced or repaired to prevent water infiltration submersible pump.

Chat Online & Leave Message

Please send email to : enquiry@apkpump.com
Or leave message in following form.
@