Shenlong Pump News Center

pump industrys new and pump technology articles

we provide advice of submersible pump installation,submersible pump working,submersible pump troubleshooting,submersible pump stopped and other pump technology articles.

Technology

Home > News > Technology

Inspection and maintenance of motor for submersible pump

Motor of submersible pump

 

The length of service life of the motor has a direct relationship with the quality of inspection and maintenance, do regular inspection and maintenance work, can prevent the occurrence of failure, ensure the safe operation of the motor. 

 Brush pump motor should keep mine sliding contact with good contact surface, brush and slip ring to the surface. The brush rod screws to tighten, brush and slip ring to maintain the distance between 2-3mm. Brush pressure to adjust the uniformity, lead to good contact surface of the slip rings no blisters pitting, no grease, no powder. The brush device and the short circuit ring should be matched with the proper, and the mechanism is sensitive and reliable. 

 1.Motor before the start of the inspection :

 1). Explosion-proof motor must ensure the explosion-proof performance, mine general type motor should ensure that the shell is good. Motor grounding in accordance with the regulations, no corrosion; the fastening screw, spring washer, flat washer, complete fastening; the anchor bolts are loose. 
 2). Motor, circumjacent environment is neat, non flammable, no water; water pumps and pipelines, no Water Leakage splash phenomenon, to prevent motor suction water mist. 
 3). Oil lubricated bearings, check the amount of oil is qualified, whether the rotation of the oil ring. 
 4). Power series, slip ring motor check whether the burn. The wear is overrun, whether the smooth surface of the slip rings. 
 5). Large children generally use the high speed motor cooling pipe and bearing lubrication system, so always check whether the valve turn wind duct and Book bearing oiler oil, the oil temperature gauge is normal and depressed. 
 6). Check the motor winding and the power cord loose people swim C bumps and burns, the terminal is fastened. 

 2. After starting the motor notes:

 1). The motor running current can not exceed the motor of the fixed current; found that the current is not stable, swing over the big should stop check. 

 2). Motor parts of the sound and vibration is normal, such as abnormal should be handled in a timely manner.